Sign In | Join Free | My carsrow.com
China Zhongdong Cable Co., Ltd. logo
Zhongdong Cable Co., Ltd.
Zhongdong Cable Co., Ltd.
Verified Supplier

1 Years

Home > Low Smoke Zero Halogen Cable >

Medium Voltage Low Smoke Zero Halogen Cable LSZH 19/33 (36)kV CU/XLPE/SWA/ LSZH EN60228

Zhongdong Cable Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Medium Voltage Low Smoke Zero Halogen Cable LSZH 19/33 (36)kV CU/XLPE/SWA/ LSZH EN60228

Brand Name : Zhongdong

Model Number : N2xh N2xh-J N2xh-O

Certification : IEC,CE,ISO,TUV

Place of Origin : Hebei,China

MOQ : Negotiable

Price : Negotiable

Payment Terms : ,L/C,T/T

Supply Ability : 100KM/Week

Delivery Time : 7-30 days based on different qty

Packaging Details : Rolls, Wooden Drums, Steel Drums, Reels or customized

Voltage : 0.6/1kV

Insulation : XLPE

Jacket : lszh

Feature : LSZH

No of Cores : 1,2,3,4,5

Standards : VDE 0276 part 604, VDE 0482-266-2, DIN EN 60332-3 / EN50266-2

Contact Now

Medium Voltage Low Smoke Zero Halogen Cable LSZH 19/33 (36)kV CU/XLPE/SWA/ LSZH EN60228



APPLICATION

For installation in ground, outdoors, indoors and in cable ducts forpower station, industry and distribution networks.


CONSTRUCTION

  • Conductor: Circular stranded, compacted copper conductor or aluminum conductor, class 2
  • Conductor Screen:Semi-conducting Compound
  • Insulation:XLPE (Cross-linked polyethylene)
  • Insulation Screen:Semi-conducting Compound
  • Metallic Screen:Copper Tape
  • Filler (only for multi core cable) Non-hygroscopic
  • Binder Tape:Non-woven fabric
  • Separation Sheath PVC (Polyvinyl chloride)
  • Armour: Single core: Aluminum Wire Armour(AWA)Three cores: Galvanized SteelTape(STA) or Galvanized Steel Wire(SWA)
  • Outer Sheath: PVC (Polyvinyl chloride), PE( Polyethylene), LSZH(Low Smoke Zero Halogen



Medium Voltage Low Smoke Zero Halogen Cable LSZH 19/33 (36)kV CU/XLPE/SWA/ LSZH EN60228Medium Voltage Low Smoke Zero Halogen Cable LSZH 19/33 (36)kV CU/XLPE/SWA/ LSZH EN60228

Medium Voltage Low Smoke Zero Halogen Cable LSZH 19/33 (36)kV CU/XLPE/SWA/ LSZH EN60228



STANDARD

VDE 0276 part 604, VDE 0482-266-2, DIN EN 60332-3 / EN50266-2


SPECIFICATION


Nominal Conductor
Area
Nominal Conductor
Dia.
Nominal Insulation
Thickness
Nominal Dia.
over Insulation
Nominal Screen
Area on Each
Core
No.and Nominal
Dia.of Screen
Wires
Nominal Dia.
Over Wire
Screen
Nominal Overall
Dia.
Approx.
Weight
mm2 mm mm mm mm2 no/mm mm mm kg/km
50 8.0 8.0 25.5 48.7 34/1.35 29.8 34.3 1700
70 9.6 8.0 27.1 68.7 48/1.35 31.4 36.1 2150
95 11.5 8.0 29.0 68.7 48/1.35 33.3 38.0 2450
120 13.1 8.0 30.6 68.7 48/1.35 34.9 39.8 2800
150 14.5 8.0 32.0 68.7 48/1.35 36.5 41.4 3100
185 16.1 8.0 33.6 68.7 48/1.35 38.1 43.2 3450
240 18.5 8.0 36.0 68.7 48/1.35 40.5 45.9 4100
300 20.7 8.0 38.4 68.7 48/1.35 42.9 48.4 4750
400 23.6 8.0 41.3 68.7 48/1.35 45.8 51.5 5750
500 26.5 8.0 44.2 68.7 48/1.35 48.7 54.9 6850
630 29.9 8.0 47.9 68.7 48/1.35 52.4 58.8 8150
800 35.9 8.0 54.0 68.7 48/1.35 58.5 65.3 10200
1000 40.2 8.0 59.5 68.7 48/1.35 64.0 71.0 12200
1200 43.8 8.0 63.5 68.7 48/1.35 68.0 75.2 14200



OUR FACTORY

Medium Voltage Low Smoke Zero Halogen Cable LSZH 19/33 (36)kV CU/XLPE/SWA/ LSZH EN60228


APPLICATION

Medium Voltage Low Smoke Zero Halogen Cable LSZH 19/33 (36)kV CU/XLPE/SWA/ LSZH EN60228Medium Voltage Low Smoke Zero Halogen Cable LSZH 19/33 (36)kV CU/XLPE/SWA/ LSZH EN60228

Medium Voltage Low Smoke Zero Halogen Cable LSZH 19/33 (36)kV CU/XLPE/SWA/ LSZH EN60228Medium Voltage Low Smoke Zero Halogen Cable LSZH 19/33 (36)kV CU/XLPE/SWA/ LSZH EN60228


FAQ

1. What’s medium voltage low smoke halogen-free armored cable all about?
Alright, so these cables are made for electrical systems that run on medium voltage. What's cool about them is that they're halogen-free, which means they produce way less toxic smoke in a fire situation. Plus, they're armored up to give them some extra physical protection.

2. What are the perks of using armored cables?
Armored cables are great because they resist mechanical damage and can stand up to tough environments. They’re pretty much like a protective shell, which keeps them safe from physical impacts, pesky rodents, and all that outside pressure.

3. Where are medium voltage low smoke halogen-free armored cables usually used?
Public buildings, industrial sites, or anywhere that has a higher fire risk.

4. How does the design of these cables impact how they’re installed?
Well, the design—especially the armoring—can mean you need some specific installation methods to keep everything working well. You’ll need to think about things like bending radius and how you connect everything up.

5. How do these cables help the environment?
By using materials that are halogen-free and producing low smoke, these cables do a lot to lessen their impact on the environment. They really boost safety in places where a lot of people are around.




 Medium Voltage Low Smoke Zero Halogen Cable LSZH 19/33 (36)kV CU/XLPE/SWA/ LSZH EN60228 Manufactures

Medium Voltage Low Smoke Zero Halogen Cable LSZH 19/33 (36)kV CU/XLPE/SWA/ LSZH EN60228 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Zhongdong Cable Co., Ltd.
*Subject:
*Message: